TopCon family TC.G options and accessories

Code / link Short description of option / accessory 

Operating
units



HMI Front panel control unit, integrated in the front of the unit
RCU.DT Remote control unit desktop, with cable lenght 2 or 5 or 10 metres, max 40 metres,
RCU.RM Remote control unit for front panel 19" rackmount with cable length 2 or 5 or 10 metres, with or without emergency stop button

Multi-unit
operation

 
 CANCABLE  Connecting cable for multi-unit operation or for RCU or TC.LIN, lenght 2 or 5 or 10 metres
 MAC  Master Array Controller, required for multi-unit systems with more than 16 power supplies
 MACInterface  Interface for MAC on rear panel of power supply, with MACCable (max 40 metres)

Control
interfaces

 
RS232REAR RS232 in front and rear panel, not simultaneously usable
RS422 RS422 in rear panel, RS232 in front panel, not simultaneously usable
CANOPEN

Interface CAN/CANopen integrated in rear panel, RS232 only in rear panel
Download: 

- Manual (installation / use): en  de
USB Interface USB integrated in rear panel, includes option RS232REAR; standard RS232 on front panel not usable
Download:

USB-driver for Windows (7, 8, 8.1, 10)

zip
USB installation manual (v1.1)
RS422 Differential serial interface RS422 on rear panel, not simultaneously usable with RS232  
- Manual (installation / use): en pdf16x16  de pdf16x16
ETHERNET Ethernet option card, internal interface card for accessing the TopCon by ethernet data transmission (replaces old transformer box).
Download:
- Manual (installation / use): en pdf16x16  de pdf16x16
- Driver: zip zip
ETHERNET.HR External unit Ethernet to RS232 converter, top hat rail mount. If required, option RS232REAR must be ordered separately
ETHERNET.DT External unit Ethernet to RS232 converter, desktop. If required, option RS232REAR must be ordered separately
IEEE
Interface GPIB / IEEE488.2 / SCPI integrated in rear panel, RS232 only on rear panel. RS232 in the front not usable.
cannot be combined with CANopen nor with USB;(limited functionality, refer to TopCon support for further informations)
Download:
- Manual (installation / use): en pdf16x16  de pdf16x16
PROFIBUS Profibus DP 485 to RS232 converter, external converter unit, desktop; option RS232REAR must be ordered separately, if required
OptoLink Rear panel integrated fiber optic interface (ST) for power supplies
OptoRS232.HR Fiber Optic (ST) to RS232 converter, external converter unit, top hat rail mount for power supply; RS232REAR to be ordered separately, if required
OptoUSB.DT Fiber Optic (ST) to USB" converter, external converter unit, desktop for USB interface on PC
OptoCable Fiber Optic Cable, lengths from 5 metres to 100 metres

Application
software



TFEAAPControl Integrated function generator, AAP facility included
SASControl SAS application support program, LabView
BatControl Battery testing solution (Application software)
BatSim Battery simulation solution (Application software)
FuelCellSim  Fuel cell simulation software, for development and process automation; TFEAAPControl is also necessary
CapSim Capacitor simulation (Application software)

Safety

 
PAC
Protection against accidental contact of output current bars  en  de
RPP   Protection againts reverse polarity of the load (e.g. when charging/discharging a battery)
ISR Integrated Safety Relay providing shutdown safety category 2/3 according to EN 13849-1
- Option ISR X107 Safety Relay en  de
- Option ISR X112 Safety Relay en  de
VLI Voltage limit indicator

Environmental
conditions

 
LAE
Liquid to air heat exchanger unit, 19-inch rack-mount, 4HU  en
AIRFILTER Front panel airfilter for units 6U and 9U height
LC Integrated liquid cooling of the power stage
RUGG.ENV.P Protection against humidity and pollution; protective coating of PCBs
RUGG.SAV.P Ruggedization against shock and vibrations; mechanical strenghtening of structure and connections

Linear
postprocessors

 
TC.LIN.26.1000.13/26 Linear post-processor unit (26 kW, 1000 VDC, 13/26 A)
TC.LIN.40.1000.20/40 Linear post-processor unit (40 kW, 1000 VDC, 20/40 A)
TC.LIN.45.1000.45 Linear post-processor unit (45 kW, 1000 VDC, 45 A)
TC.LIN.75.1500.50 Linear post-processor unit (75 kW, 1500 VDC, 50 A)
TC.LIN.75.1500.50.LC  Linear post-processor unit with integrated liquid cooling (75 kW, 1500 VDC, 50 A)

Output range
modifications

 
NSOV Non-standard DC output voltage (if possible)
NSOC Non-standard DC output current (if possible)

Input range 
modifications

 
 NSIV Non-standard AC input voltage (if possible) 
 ATU.80.480/400 Autotrafo unit 480<==>400 VAC in 19-inch rack, with main switch, air cooling, NTC control

Miscellaneous

 
X113 24 VDC external supply if controller board for TopCon Quadro 9HU (20 and 32 kW)

 

There exist further enhancements to mechanical and thermal requirements, shortened as so-called ruggedized version.

 

 

Regatron AG
Feldmuehlestrasse 50

9400 Rorschach
Switzerland

Tel. +41 71 846 67 44
Fax +41 71 846 67 77
tc.support (at) regatron.ch