TC.DSS Series

Programmable bidirectional DC / DC converter.

Our answer to demanding DC / DC conversion requirements !

Series Overview


TC.DSS Series

Features

  • TopCon DC/ DC Source Sink technology enables full bidirectional operation
  • Compact design with integrated EMI - and Sine filters
  • Constant voltage (0 – 100 %), constant current (0 – 100 %) and constant power operation (5 – 100%)
    with automatic and fast crossover and mode indication. Internal resistance simulation.
  • Graduated product line: 65 VDC, 130 VDC, 400 VDC, 500 VDC, 600 VDC, higher voltages with series
    connection up to 1500 VDC.
  • Power categories of 20 kW and 32 kW are available for each nominal output voltage.
  • Optional extras and accessories complete the product line of power supply units.
  • Modular concept for easy power increase: Parallel, series, matrix or multiload master-slave-operation.
  • High efficiency at a low cost, resulting from the application of innovative IGBT and transformer technology. Primary switched. Galvanicly isolated.
    Full digital control and regulation.
  • A user-friendly PC program, the operating and service software TopControl, enables the user to communicate with the power supply.
  • TopControl installation file, LabVIEW® and C/C++ C#/.NET API (DLL file) are included in the scope of delivery.
  • CE conformity
  • Swiss made: Developed, manufactured and tested in Switzerland by Regatron AG.

Voltage- / Power- / Current-Range


Technical Datasheets


Options and Accessories


Option Code Short description of option / accessory Products
Operating Units
HMI Front Panel Integrated Control Unit HMI
RCU.RM 19-Inch Rack-Mount Remote Control Unit includes CANCable, specify length 2m, 5m, 10m, max. 40m RCU.RM
RCU.RM.2CH 19-Inch Rack-Mount Remote Control Unit with Emergency Stop Button (2-Channel) includes CANCable, specify length 2m, 5m, 10m, max. 40m RCU.RM.2CH
RCU.DT.1CH Desk-Top Remote Control Unit with Stop Switch (1-Channel); with cable length 2m, 5m, 10m, max. 40m RCU.DT.1CH
Multi-Unit Operation
CANCable Connecting Cable for Multi-Unit Operation, connects also bus participants like RCU, TC.LIN; Length 2m, 5m, 10m
MAC Master Array Controller required for multi-unit systems with more than 16 power supplies MAC
MACInterface Interface for MAC on Rear Panel of Power Supply; includes MACCable, specify length 2m, 5m, 10m, max. 40m MACInterface
Control Interfaces
CANOPEN Rear Panel Integrated CAN/CANopen Interface includes RS232REAR; standard RS-232 on front panel not usable CANOPEN PDF (1.23MB)
CANmp Rear Panel Integrated CAN Interface CANmp PDF (359KB)
LXI Rear Panel Integrated LXI Interface; includes RS232REAR; standard RS-232 on front panel not usable LXI
ETHERNET Rear Panel Integrated Ethernet Interface includes RS232REAR; standard RS-232 on front panel not usable ETHERNET PDF (941KB)
ETHERNET.HR Ethernet <=> RS-232 Converter, External Converter Unit, Top Hat Rail Mount; option RS232REAR must be ordered separately, if required
IEEE Rear Panel Integrated GPIB / IEEE488.2 / SCPI Interface includes RS232REAR; standard RS-232 on front panel not usable IEEE PDF (971KB)
RS232REAR Rear Panel Integrated RS-232 Interface; standard RS-232 on front panel available, not simultaneously usable RS232REAR
RS422 Rear Panel Integrated RS-422 Interface; standard RS-232 on front panel available, not simultaneously usable RS422 PDF (250KB)
USB Rear Panel Integrated USB Interface includes RS232REAR; standard RS-232 on front panel not usable. Driver Download USB ZIP (3.53MB)
Application Software
TFEAAPControl Function Generating Engine, Time-based and Parametric Programming PDF (855KB)
User Safety
PAC.G.DC DC Terminal Protective Cover (for TC.GSS); transparent polycarbonate, quick-acting closure PAC.G.DC PDF (655KB)
ISR Integrated Safety Relay for Increased Emergency Stop Reliability ISR PDF (467KB)
VLI Voltage Limit Indicator (0...1500VDC, passive) Top Hat Rail Mount; Stand alone, no cables included VLI PDF (528KB)
Environmental Conditions
AIRFILTER.9 Front Panel Airfilter (for Power Supplies 9HU); screw-on metal frame, replaceable filter mat AIRFILTER.9
LC Liquid Cooling
RUGG.ENV.G Protection against Humidity and Pollution (for TC.GSS); protective coating of PCBs PDF (100KB)
RUGG.SAV.G Ruggedization against Shock and Vibration (for TC.GSS); mechanical strengthening of structure and connections PDF (100KB)
Output Range Modifications
NSOV Non-Standard DC Voltage; contact factory for feasibility
NSOC Non-Standard DC Current; contact factory for feasibility
Input Range Modifications
NSIV Non-Standard AC Voltage; contact factory for feasibility
Service
Calib.G.3P 3-Point Calibration and Adjustment (for TC.GSS and TC.ACS); does not include maintenance and repair work
Calib.G.10P 10-Point Calibration and Adjustment (for TC.GSS and TC.ACS); does not include maintenance and repair work
Calib.Protocol Calibration Protocol
Warranty +1J Warranty extension +1 year
Warranty +2J Warranty extension +2 years

Related Documents and Files


Name Explanation Type/size
Software
TopControl Software
V4.11.00

Operating, service and diagnostic-Software for TopCon power supplies
Release Notes

ZIP (37.27MB)
TopControl Software Information
V01.00

TopControl Software Information Sheet. PC-Software for operation and service of TopCon device series

PDF (855KB)
Brochures
REGATRON Product Overview
19081401

DC and AC Power Sources, Programmable and Modular

PDF (215KB)
Application Portfolio

Application Portfolio Regatron Division Programmable Power Supplies

PDF (1.49MB)
Manuals
TC.DSS Serie Benutzerhandbuch DE
V01.05

Benutzerhandbuch für TC.DSS Serie

PDF (2.79MB)
Error List
V11.51

Error List for TopCon devices, HMI, TC.RCU and Software TopControl

PDF (1,018KB)
Fehlerliste DE
V11.51

Fehlerliste für TopCon Geräte, HMI, TC.RCU und Software TopControl

PDF (1.09MB)
Applications
Application Success Story Versatility

Universal Technical Laboratory Equipment Needed? Versatile Solution provided by Regatron AG

PDF (749KB)
Driver
USB Driver

USB Interface Driver for Windows (7,8,8.1,10)

ZIP (3.53MB)
ETHERNET-Driver

ETHERNET Interface Driver Interface for Windows (7,8,8.1,10)

ZIP (2.35MB)
ETHERNET-Driver Manual
V01.71

ETHERNET-Driver Interface Installation Manual

PDF (941KB)
Programming Interfaces
Firmware versions

Please refer to TopCon Support for assistance. Please attach a screenshot of the "Device Info" tab of TopControl.

Firmware versions
Programming Overview

Manual and software-based control of TopCon devices - Introduction and General Overview

PDF (307KB)
Low-Level Protocol
V0.2.16

Description of the Low-Level protocol, which is the basic protocol to communicate | TC.P and TC.GSS Series

PDF (2.07MB)
TCIO API
V3.88.00

TopCon Input-Output library with ANSI C interface. Windows & Linux (incl. documentation) | TC.P and TC.GSS Series

ZIP (7.58MB)
TopCon API
V1.1.0.542

.NET Programming API, true object-oriented high-level access. Windows only (incl. documentation) | TC.P and TC.GSS Series

ZIP (30.10MB)
LabVIEW for TC.P and TC.GSS
V1.1.0.542

TopCon LabVIEW files and examples | TC.P and TC.GSS Series

ZIP (11.39MB)
LabVIEW for SASControl
V1.00.01

TopCon LabVIEW files and examples for SASControl | TC.P and TC.GSS Series

ZIP (863KB)
LabView for GPIB
V1.00.01

TopCon LabVIEW GPIB files and examples | TC.P and TC.GSS Series

ZIP (730KB)
Controller Parameter
V1.23e

Background information and "how to" tune the parameterization of the TopCon Quadro /TC.Gxx Series controllers.

PDF (2.68MB)
Options and Accessories
CANOPEN
V02.62

CANOPEN Interface Manual - The option TC.CANOPEN enables the TopCon Quadro power supply to be programmed by a controller over CAN bus. The CANopen protocol allows the integration of the TopCon power supply into an existing CANopen network.

PDF (1.23MB)
CANOPEN EDS TC.GSS
DA613V_0009 V00

CANOPEN Electronic Data Sheet TC.GSS

EDS (15KB)
CANmp
V01.01

Rear Panel Integrated CAN Interface

PDF (359KB)
Standard CANmp Configuration

Standard CANmp Configuration - TopCon Quadro & TC.GSS

DBC (4KB)
TC.RS422
V01.20

TC.RS422 Interface Option Manual - Diagnostics and control connection

PDF (250KB)
IEEE
V02.62

GPIB / IEEE488.2 / SCPI Interface Manual

PDF (971KB)
PACOB
V01.10

Supplement to the Manual. Protection against accidental contact of output current bars. 9U Units

PDF (655KB)
ISR X107
V05.10

Integral Safety Relay ISR - X107

PDF (444KB)
ISR X112/ X112-2
V01.35

Integral Safety Relay ISR - X112; Option X112/ X112-2 (dual channel)

PDF (467KB)

Pictures