Pre-Configured Cabinet-Solutions for EMC Testing

Discover the pre-configured systems for conducted full and pre-compliance EMC testing. The tables below depict pre-configured solutions tailored to your specific requirements in terms of power and test type. Besides the EMC immunity test systems, system solutions are also available enabling 

EMC emission and immunity tests according to IEC/EN 61000-3-X and IEC/EN 61000-4-X standards. The contents of REGATRON’s standards packages are listed in detail after the EMC system solutions.

Full Compliance EMC Immunity Test System Power [kVA] Voltage [VRMS] Current [ARMS] Frequency [Hz]
Bandwidth [Hz]
Voltage Slope [µs] Peak current [Apeak]
50
30
3 x 0…305
(L-N)
3 x 0...528
(L-L)
3 x 0…75
3 x 0…43
50/60
0...5000
1…5 ≤1000
≤10 ms
for sine signal
System Components
EMC Test System 50 kVA / 3 x 0…75 ARMS: TC.ACS.50.528.4WR.HC
EMC Test System 30 kVA / 3 x 0…43 ARMS: TC.ACS.30.528.4WR.S
Standards package IEC/EN 61000-4-X
Voltage Slope Enhancer TC.VSE.50.528.2WR.S enables voltage dips, interruptions,
fluctuations according to IEC/EN 61000-4-11, -4-27, -4-34
Pre-Compliance EMC Immunity Test System Power [kVA] Voltage [VRMS] Current [ARMS] Frequency [Hz]
Bandwidth [Hz]
Voltage Slope [µs] Peak current [Apeak]
50
30
3 x 0…305
(L-N)
3 x 0…528
(L-L)
3 x 0…75
3 x 0…43
50/60
0...5000
≤100 ≤204
≤1 s
≤122
≤1 s
System Components
EMC Test System 50 kVA / 3 x 0…75 ARMS: TC.ACS.50.528.4WR.HC
EMC Test System 30 kVA / 3 x 0…43 ARMS: TC.ACS.30.528.4WR.S
Standards package IEC/EN 61000-4-X
Full Compliance EMC Test System Power [kVA] Voltage [VRMS] Current [ARMS] Frequency [Hz]
Bandwidth [Hz]
Voltage Slope [µs] Peak current [Apeak]
50
30
3 x 0…305
(L-N)
3 x 0…528
(L-L)
3 x 0…75
3 x 0…43
50/60
0...5000
1…5 ≤1000
≤10 ms
for sine signal
System Components
EMC Test System 50 kVA / 3 x 0…75 ARMS: TC.ACS.50.528.4WR.HC
EMC Test System 30 kVA / 3 x 0…43 ARMS: TC.ACS.30.528.4WR.S
Standards package IEC/EN 61000-3-X with LMG671-integration
Standards package IEC/EN 61000-4-X
Power Analyzer LMG671 for flicker and current harmonics measurement according to
IEC/EN 61000-4-7, -4-15
Flicker Impedance Network TC.FLK75.2WR.S according to IEC/TR 60725
Voltage Slope Enhancer TC.VSE.50.528.2WR.S enables voltage dips, interruptions,
fluctuations according to IEC/EN 61000-4-11, -4-27, -4-34
Pre-Compliance EMC Test System Power [kVA] Voltage [VRMS] Current [ARMS] Frequency [Hz]
Bandwidth [Hz]
Voltage Slope [µs] Peak current [Apeak]
EMC Emission Testing according to Standards IEC/EN 61000-3-X 50
30
3 x 0…305
(L-N)
3 x 0…528
(L-L)
3 x 0…75
3 x 0…43
50/60
0...5000
≤100 ≤204
≤1 s
≤122 A
≤1 s
System Components
EMC Test System 50 kVA / 3 x 0…75 ARMS: TC.ACS.50.528.4WR.HC
EMC Test System 30 kVA / 3 x 0…43 ARMS: TC.ACS.30.528.4WR.S
Standards package IEC/EN 61000-3-X with LMG671-integration
Standards package IEC/EN 61000-4-X
Grid Impedance Simulation for flicker impedance network simulation
Power Analyzer LMG671 for flicker and current harmonics measurement according to
IEC/EN 61000-4-7, -4-15

Content of standards packages

The standards package IEC/EN 61000-3-X contains the standard tests according to the following table.

Standards package IEC/EN 61000-3-X
IEC/EN 61000-3-2 Limits for harmonic current emissions (equipment input current ≤16 A per phase)
IEC/EN 61000-3-3 Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems,
for equipment with rated current ≤16 A per phase and not subject to conditional connection
IEC/EN 61000-3-11 Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems -
Equipment with rated current ≤75 A and subject to conditional connection
IEC/EN 61000-3-12 Limits for harmonic currents produced by equipment connected to public low-voltage systems
with input current >16 A and ≤75 A per phase

The standards package IEC/EN 61000-4-X contains pre-programmed test sequence for standard tests according to the following table.

Standards package IEC/EN 61000-4-X
IEC/EN 61000-4-11 Voltage dips, short interruptions and voltage variations immunity tests for equipment
with input current up to 16 A per phase
IEC/EN 61000-4-13 Harmonics and interharmonics including mains signaling at AC power port,
low frequency immunity tests
IEC/EN 61000-4-14 Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase
IEC/EN 61000-4-27 Unbalance, immunity test for equipment with input current not exceeding 16 A per phase
IEC/EN 61000-4-28 Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
IEC/EN 61000-4-34 Voltage dips, short interruptions and voltage variations immunity tests for equipment
with mains current more than 16 A per phase
Contact REGATRON for AC power solutions – programmable AC power supplies for grid simulation and testing