G5.IND Series
Options and Functions for the G5.IND Series
CAN Interface
The CAN multi-protocol (CANmp) interface has a 1 kHz data rate, a 16-bit resolution, and is adaptable to any proprietary CAN bus. In addition, it supports dbc file handling.
Order Code: CANmp
EtherCAT Interface
The EtherCAT slave interface (ECAT) supports configuration by ESI file and communicates in a 1 kHz cycle. It transmits the entire process data in the same cycle, i.e. commands, actual states, and actual values. Acyclic communication via mailbox for device configuration is also possible.
Order Code: ECAT
SCPI Interface
SCPI, Standard Commands for Programmable Instruments, are ASCII s trings, which are sent to the device over TCP/IP using the LAN socket. They can perform set operations or query operations.
Order Code: SCPI
WebAPI (REST)
The integrated WebAPI (REST) controller allows convenient operation of the power supply via the WebAPI (REST) interface.
Order Code: WebAPI
Integrated Safety Relay
Integrated safety relay (ISR) for increased emergency stop reliability, supporting performance level PL c / PL e according to EN ISO 13849.
Order Code: ISR
AC Filter Discharge
Discharging of the AC filter (XCD), is mandatory when using the device with a plug connection. XCD ensures a discharge time of the AC filter less than 1 s as required by EN 62477-1
Order Code: XCD
Protection Covers
The different protective covers are designed for integration into 19″ rack systems or for use as a tabletop device. The cover for cabinet integration provides protection against accidental contact, whereas the cover for the tabletop version requires touch-proof protection in accordance with standard EN 62477-1.
Order Code: PAC

AirFilter
Front panel mounted air filter (AirFilter), recommended for use in dusty environments and with IP20 cabinets
Order Code: Airfilter
Rack Integrated System Solutions
- Mobile rack solutions on castors up to 162 kW
- Stationary rack solutions up to 324 kW
- IP54 protection for air or liquid-cooled systems
- Third-party product integration and numerous safety options
- Insulation monitoring integrated into safety circuit; activation and settings on display
- Easy reconfiguration between parallel or single operation


Need the Right Power Solution?
We’ll help you define the ideal setup.